General Descriptions:
SG330KTL is using low-frequency isolation transformer for protective purpose. Its wider input voltage range ensures more combinations of the PV arrays. Moreover, optical fiber isolation technology has been adopted to increase its anti-interference ability under the circumstances of multiple inverters installation. In addition, optimized circuit and structural design has improved system thermal efficiency which enhancing system reliability and stability. Reinforced protection functions, including the DC ground fault protection, make it the best product for large scale PV power plant.
Technical Features:
• Power reduction (100%, 60%, 30%, 0%) meet German EEG requirements
• Reactive Power Control with power factor from 0.95 lagging to 0.95 leading
• Using advanced IGBT modules
• Max. efficiency at 98.1%
• Easy Installation and maintanence
• Precise output power metering
• Multilingual monitoring and control interface
• Auxiliary heater (optional)
• Max. working altitude at 6000m (operation with derating above 3000m)
• High quality german brand enclosure
• Low voltage ride through
• CE certification
Communications:
• RS485/Ethernet/GPRS interfaces
• Computer monitoring software
Safety:
·Full protection functions: over-voltage protection, short-circuit protection, islanding protection, over-heat protection
• DC ground-fault protection
·Over-load protection
·Standards complied: EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,EN61000-3-2, EN61000-3-3, EN60164-1-1,EN55022, EN50178
Download: SG330KTL [320KB] || User Manuals-IM [2MB] || User Manuals-OM [2MB]
Technical Specifications
| MODEL | SG330KTL |
| DC DATA | |
| Max. DC Voltage | 900Vdc |
| MPP Voltage Range | 500~820Vdc |
| Max. DC Power | 360kWp |
| Max. Input Current | 660A |
| Recommend PV Array Open Circuit Voltage | 700V |
| AC DATA | |
| Rated Output Power | 330kW |
| Rated Grid Voltage | 315Vac |
| Grid Voltage Range | 250~362Vac |
| Rated Grid Frequency | 50Hz/60Hz |
| Grid Frequency Range | 47~51.5Hz/57~61.5Hz |
| Output Current THD | <3% (at nominal power) |
| DC Current Injection | <0.5% of rated inverter output current |
| Power Factor | 0.95(lagging)~0.95(leading) |
| SYSTEM | |
| Max. Efficiency | 98.1% |
| Euro. Efficiency | 97.6% |
| Protection Degree | IP20 (indoor) |
| Power Consumption at Night | <100W |
| Operating Temperature | -25~+55℃ |
| Cooling Method | controlled forced-air cooling |
| Relative Humidity | 0~95%, non-condensing |
| Max. Working Altitude | 6000m (operation with derating above 3000m) |
| Display AND COMMUNICATIONS | |
| Display | touch screen LCD |
| Standard Comm. Interfaces | RS485 |
| Optional Comm. Interfaces | Ethernet/GPRS |
| MECHANICAL DATA | |
| Dimensions(WxHxD) | 1800x2180x850mm |
| Net Weight | 1350kg |