General Descriptions:
SG330KTL is using low-frequency isolation transformer for protective purpose. Its wider input voltage range ensures more combinations of the PV arrays. Moreover, optical fiber isolation technology has been adopted to increase its anti-interference ability under the circumstances of multiple inverters installation. In addition, optimized circuit and structural design has improved system thermal efficiency which enhancing system reliability and stability. Reinforced protection functions, including the DC ground fault protection, make it the best product for large scale PV power plant.

Technical Features:
 • Power reduction (100%, 60%, 30%, 0%) meet German EEG requirements
 • Reactive Power Control with power factor from 0.95 lagging to 0.95 leading
 • Using advanced IGBT modules
 • Max. efficiency at 98.1%
 • Easy Installation and maintanence
 • Precise output power metering
 • Multilingual monitoring and control interface
 • Auxiliary heater (optional)
 • Max. working altitude at 6000m (operation with derating above 3000m)
 • High quality german brand enclosure
 • Low voltage ride through
 • CE certification

Communications:
 • RS485/Ethernet/GPRS interfaces
 • Computer monitoring software

Safety:
·Full protection functions: over-voltage protection, short-circuit protection, islanding protection, over-heat protection
 •  DC ground-fault protection
·Over-load protection
·Standards complied: EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,EN61000-3-2, EN61000-3-3, EN60164-1-1,EN55022, EN50178

 Download:   SG330KTL [320KB]   ||  User Manuals-IM [2MB]  ||  User Manuals-OM [2MB]


Technical Specifications    

MODEL  SG330KTL 
DC DATA   
Max. DC Voltage 900Vdc
MPP Voltage Range 500~820Vdc 
Max. DC Power 360kWp 
Max. Input Current 660A 
Recommend PV Array Open Circuit Voltage 700V
AC DATA   
Rated Output Power 330kW 
Rated Grid Voltage 315Vac
Grid Voltage Range 250~362Vac
Rated Grid Frequency 50Hz/60Hz
Grid Frequency Range 47~51.5Hz/57~61.5Hz
Output Current THD <3% (at nominal power)
DC Current Injection <0.5% of rated inverter output current
Power Factor 0.95(lagging)~0.95(leading)
SYSTEM   
Max. Efficiency 98.1%
Euro. Efficiency 97.6%
Protection Degree IP20 (indoor) 
Power Consumption at Night <100W
Operating Temperature -25~+55℃
Cooling Method controlled forced-air cooling
Relative Humidity 0~95%, non-condensing
Max. Working Altitude 6000m (operation with derating above 3000m)
Display AND COMMUNICATIONS  
Display touch screen LCD
Standard Comm. Interfaces RS485
Optional Comm. Interfaces Ethernet/GPRS
MECHANICAL DATA   
Dimensions(WxHxD) 1800x2180x850mm
Net Weight 1350kg
 



About Sungrow|Survey|Website|Copyright